Type | EN61 |
---|---|
Features | EU type-examination certificate DGR, EU type-examination certificate GGV, UKCA type-examination certificate GGV |
max. pressure: PS | 16 bar |
According to DVGW Worksheet G 607 "Liquid gas systems in inhabited recreational vehicles and for residential purposes in other road vehicles – operation and testing", pressure regulators, among others, must be replaced no later than 10 years after the date of manufacture. If the operating pressure of the system is 30 mbar, a regulator according to EN 16129 Appendix D must be used when replacing the regulator in accordance with G 607. For liquid gas systems in vehicles with an operating pressure of 50 mbar, there is protection of the existing standard. There is no obligation to convert to 30 mbar.
For connection to gas cylinders, for pressure regulation to the nominal pressure of the gas appliance.
Please note:
- Outlets that are not used must additionally be sealed with a blind nut.
- Pressure regulators with an outlet pressure of 29 mbar are not suitable for use in Germany!